高效换热管中R22传热特性的试验研究与分析
【摘要】针对海水冷却的特点和要求,研究了R22在高效换热管管内蒸发(管径16mm)和管外冷凝(管径19mm)的传热和压降特性,并就传热特性与相关文献报道进行了比较。实验结果表明,耐腐蚀铜合金高效换热管作为冷凝器时,其传热性能比普通换热管(如光滑管)要高出一倍左右。这些研究和分析对热泵空调换热器优化设计及海水高低温热源的应用具有重要意义。
EXPERIMENTAL RESEARCH ON CONDENSING AND
EVAPORATING HEAT TRANSFER CHARACTERISTICS OF
REFRIGERANT R22 IN AN EFFICIENT HEAT TRANSFER TUBE
Zhang Xiaosong Zhou Leping Shi Mingheng
(Department of Power Engineering,Southeast University,NanJing 210096)
Abstract:Condensing and evaporating heat transfer and pressure drop refrigerant R22,flowing outside a 19mm OD(for condensation) and inside a 16mm OD(for evaporation)were investigated.The performance characteristics of heat transfer are compared with data from literature reports.The results show that the performance characteristics of anti-rotten efficient cooper alloy tube as a condenser are about two times of those common tubes(such as smooth tubes).These research and analysis are useful in the optimization design of heat exchanger in a heat pump air-condition.
Keywords:high efficiency heat exchanging tube,performance characteristics of heat transfer,evaporation,condensation,experimental research
0 引 言
不断改善和提高传热效果、强化传热过程是提高制冷剂和热泵设感阅艿闹匾谌荨L乇鹗窃谌缺弥校艽蟠蠼档腿缺没蝗绕髦械氖导饰虏睿佣岣呷缺玫纳路龋欣谔岣呦低车腃OP值。本课题研究的高效换热管是一种用海水冷却的制冷装置中的耐腐蚀铜合金高效换热管。
由于受到环境和发展的压力,淡水资源更加宝贵,而海水不仅数量巨大而且无论是盛夏还是严冬均有比较适中的温度。积极探索用海水进行冷却,尤其是将海水用作热泵的低温热源更具积极意义。因此,开发海水冷却的高效换热管,研究其与制冷剂的传热性能,就显得尤为重要。
利用作者与某空调集团公司合作研制的具有较高测控范围和精度的实验系统,对两种不同的耐腐蚀铜合金为材料的高效换热管分别进行了以R22为工质的管内蒸发和管外冷凝传热性能的实验研究。
1 实验系统及过程简介
1.1 实验系统
实验系统如图2所示。该实验系统能在较大范围内为换热试件提供所需的制冷剂状态和流量。实验系统包括三个部分:①热压缩循环[1],是一个可向蒸发或冷凝试件提供可变制冷剂流量的热模拟系统,并能稳定提供实验所需的制冷剂状态;②水循环系统,能稳定提供实验所需的水流量及水温状态;③数据采集与微机测试系统,能进行状态自动控制和自动巡回检测及数据处理。
1.2 实验管段
图1所示为实验管段的截面图,其中左侧为冷凝管,右侧为蒸发管。蒸发管管径
16×1.1,管段有效长度ly=1.1m,换热管材料为T2紫铜;换热管内壁有100道内微槽,槽深0.2mm,槽距1.0mm,槽宽0.5mm;换热器为多头内螺纹高效管。冷凝管管径
19×2.2,管段有效长度ly=1.1m,换热管材料为B30镍白铜;换热管外一周有60个外翅,翅高0.6mm,翅距0.7mm,管外有来复线;换热器为多头外螺纹高效管。试件加工成套管式结构,为逆流换热模式。管段在布置时都约有15°的倾斜角度,以便制冷剂的及时流出。

图1 实验管段截面图


图2 实验设备原理图
1.3 实验过程
实验时,由冷凝管入口压力来控制冷凝温度,由过热器来控制冷凝管入口所需的过热度并保持恒定。同样,由蒸发管出口压力来控制蒸发温度等。由水与R22的温差来决定大体的热流温度,然后不断改变水侧流量,电子膨胀阀会自动调节开度以改变制冷剂流量,保持出口过热度(或过冷度)在允许的范围内(见表1),系统达到稳定后,数据采集系统中所有的测量点将被每隔12s扫描一次,共连续测试12min,取平均值。通过比较制冷剂和水侧换热量来判断所测结果是否有效。
表1 制冷剂状态参数范围和测控精度
| 实验工况参数 | 参数范围(℃) | 测控精度(℃) |
| 冷凝器冷凝温度 | 35—65 | ±0.5 |
| 冷凝器入口温度 | 50—130 | ±0.5 |
| 冷凝器出口过冷度 | 3—10 | ±1.0 |
| 蒸发器蒸发温度 | -15—15 | ±0.5 |
| 蒸发器出口过热度 | 3—30 | ±1.0 |
2 数据处理 制冷剂R22侧由直测的出口温度、压力,通过计算软件自动求出焓值,即
换热量为
其中G为制冷剂质量流量〔kg/s〕。
其中,Gw为水的质量流量〔kg/s〕,Cp为水的比热容〔kJ/kg.℃〕,Δt为水的进出口温差(℃)。入稳判据为
其中,(Qr+Qw)/2=Qave为平均换热量。这样,换热管的传热系数为
其中,F为传热面积(m2);以未加工微翅前的管径计算,Δtm=|tw,ave-tr|,它为制冷剂和水的传热温差;tw,ave为水侧平均温度,tr为制冷剂饱和温度(做蒸发实验时为蒸发温度,做冷凝实验时为冷凝温度)。 3 实验结果及讨论 表2 R22冷凝实验数据 |
| Pt. | v | q | k | ΔP | |
| (m/s) | (W/m2) | (W/m2.K) | (Pa) | ||
| th= 70℃ |
1 | 3.1792 | 66425 | 6948.9 | 3040 |
| 2 | 3.1855 | 64672 | 6779.1 | 3080 | |
| 3 | 2.7375 | 61051 | 6448.3 | 3040 | |
| 4 | 2.7368 | 61177 | 6468.5 | 3030 | |
| 5 | 2.1422 | 56113 | 5999.4 | 3010 | |
| 6 | 1.6713 | 50918 | 5530.1 | 2960 | |
| 7 | 1.6776 | 50241 | 5441.6 | 2950 | |
| 8 | 1.5187 | 48021 | 5227.9 | 2930 | |
| 9 | 1.5254 | 48133 | 5237.3 | 2910 | |
| 10 | 1.2679 | 44560 | 4902.3 | 2890 | |
| 11 | 1.2667 | 44659 | 4916.1 | 2910 | |
| 12 | 1.0936 | 41473 | 4598.3 | 2870 | |
| 13 | 1.0924 | 40932 | 4540.3 | 2830 | |
| 14 | 0.9215 | 36735 | 4102.1 | 2800 | |
| th= 90℃ |
1 | 0.9186 | 37068 | 4136 | 2470 |
| 2 | 1.6044 | 51347 | 5608.3 | 2530 | |
| 3 | 1.9676 | 54435 | 5852.3 | 2450 | |
| 4 | 2.2271 | 56432 | 5997.5 | 2410 | |
| 5 | 2.6675 | 62489 | 6625.4 | 2480 | |
| 6 | 1.3157 | 46515 | 5125.6 | 2390 | |
| 7 | 1.3175 | 46876 | 5157.5 | 2390 | |
|
图3 由实验结果可见,该换热器的换热系数较高,一般在6000W/(m2.K)左右,在相同条件下比平滑管高出一倍左右。这一方面是由于冷凝实验是在管外进行的,有利于气体的冷凝,强化了换热作用;另一方面,换热面积的增大,也使换热过程增强。有关与光滑管换热性能的比较可以参考本文第4部分内容。另外,由该图可见,过热温度为90℃时的换热系数较70℃时高,这说明换热系数还与过热温度有关;但在同一流速下换热系数的差距并不大。 表3 R22蒸发实验数据 |
| Pt. | v | q | k | ΔP |
| (m/s) | (W/m2) | (W/m2.K) | (Pa) | |
| 1 | 1.0539 | 26741 | 2028.7 | 1910 |
| 2 | 0.8698 | 24513 | 18 9 | 1500 |
| 3 | 0.8740 | 26028 | 1977.1 | 1600 |
| 4 | 0.7458 | 23900 | 1793.6 | 1510 |
| 5 | 0.7461 | 24410 | 1848 | 1550 |
| 6 | 0.7562 | 24567 | 1851.4 | 1600 |
| 7 | 0.9765 | 27787 | 2094.7 | 1700 |
| 8 | 0.9783 | 28001 | 2111.7 | 2350 |
| 9 | 1.1454 | 31008 | 2336.6 | 2320 |
| 10 | 1.1482 | 30766 | 2317.5 | 1190 |
|
图4 Φ16×1.1内螺纹铜管内R22蒸发实验k—v、dP—q关系曲线 由实验结果可见,该换热器的换热系数较低,一般在2000〔W/m2.K〕左右,在相同条件下甚至比一些平滑管还低。经对换热管进行仔细的观察,发现该换热管的管内螺纹不明显,且不尖锐,难以形成有效的强化沸腾核心,也就难以起到强化换热作用。 4 与有关实验的比较
图5 Φ16.3×1.0内微翅铜管内R11
图6 Φ9.52×0.76铜管内R22冷凝实验k—m图 考虑实验管段的长度和实验条件不同等因素,用图3中的实验结果与以上结果进行比较可以发现,图3中换热系数范围已达到或超过图6中R22在强化管中的结果,而图6中强化管在相同条件下的换热系数是平滑管的2倍左右;在翅高没有图5中强化管显著的情况下,图3中换热系数范围也已接近R11,而在相同条件下对于平滑管中的冷凝换热系数R11远远高于R22。这些都说明该强化管的强化效果十分明显。 表4 微翅铜管数据表 |
| 翅数(个) | 螺旋角(°) | 翅高(mm) |
| 74 | 27 | 0.35 |
| 78 | 20 | 0.35 |
| 76 | 17.5 | 0.35 |
| 74 | 15 | 0.35 |
|
图7 MXTM螺旋内微翅铜管内R22蒸发实验k—m图 L M Schlager等人对平滑管和内微翅铜管做了R22的管内干式蒸发实验(蒸发温度t0=3℃)[3]。该蒸发换热管管径Φ9.52×0.76,管段有效长度ly=3.67m,换热管材料为黄铜,换热管外一周有60—70个微翅,翅高0.1—0.2mm。制冷剂质量流量控制在125—400kg/(m2.s)。其换热系数按平均换热系数计算,实验结果如图8所示。
图8 Φ9.52×0.76铜管内R22蒸发实验k—m图 上述结果表明,采用内微翅铜管作为蒸发管时,其换热强化的效果较明显,但本文报道的蒸发管实验,其换热强化效果较之不明显。 5 结束语 作者单位:东南大学动力工程系,南京 210096 参考文献 1 赵开涛,张小松等.换热实验台制冷剂供应系统的研究.东南大学学报,1998 28卷(增刊):29—33 |
Copyright © 1996-2010 China Harbin DawnHappy Heat Pipe Technology Co., Ltd.
哈尔滨晨怡热管技术有限公司 电话:0451-82589558 82589508 82589538 传真:0451-82552085 技术支持:13704813968
地址:哈尔滨市南岗区南通大街256号 邮编:150001 电子信箱:heatpipe@yahoo.cn heat-pipe@hotmail.com heat.pipe@yahoo.com.cn
本站永久域名:http://china-heatpipe.net http://heatpipe.net.cn http://rg.nx8.net http://nx8.net
中华人民共和国信息产业部ICP/IP地址信息备案:黑ICP备07500228 哈尔滨市公安局国际联网备案登记:哈公网监备2301001146