晨怡热管 >> 资料积累 >> 热管文献 >> 大型热虹吸管近室温条件下传热性能的实验研究

大型热虹吸管近室温条件下传热性能的实验研究

晨怡热管 北京工业大学 周峰 罗琳 马国远 2008-2-21 10:56:15

摘要:热管作为一种高效的传热元件,在许多领域得到了广泛的应用。本文对近室温条件下大型热虹吸管的传热特性进行实验研究,用实验结果分析热虹吸管轴向壁温分布以及充液率、倾角、管长和迎面风速对其传热性能的影响,得到了最佳充液率和倾角。
关键词:热管  热回收  实验研究

Abstract: As a high efficiency unit of heat transfer, heat pipe is widely applied in many fields. The heat transfer characteristics of the large thermosyphon are studied experimentally in this paper under the near room-temperature. The trend in axial differences in temperature is shown in the paper. Through analyzing the experiment data the article discusses the effects of filling rate,obliquity, length and head-on speed of wind on heat transfer characteristics of the heat pipe. In this condition the optimum filling rate and obliquity are found.
Keywords: heat pipe  heat recovery  experimental study

责任编辑: banye 参与评论
本站地图|热管配套|企业邮局|产品说明

Copyright © 1996-2010 China Harbin DawnHappy Heat Pipe Technology Co., Ltd.
哈尔滨晨怡热管技术有限公司   电话:0451-82589558 82589508 82589538   传真:0451-82552085 技术支持:13704813968
地址:哈尔滨市南岗区南通大街256号  邮编:150001  电子信箱:heatpipe@yahoo.cn   heat-pipe@hotmail.com heat.pipe@yahoo.com.cn 
本站永久域名:http://china-heatpipe.net     http://heatpipe.net.cn    http://rg.nx8.net     http://nx8.net  
中华人民共和国信息产业部ICP/IP地址信息备案:黑ICP备07500228  哈尔滨市公安局国际联网备案登记:哈公网监备2301001146